SBIR-STTR Award

Monolithic Multiwavelength Blue-to-IR LED for Biomedical Diagnostics
Award last edited on: 4/1/2019

Sponsored Program
STTR
Awarding Agency
NSF
Total Award Amount
$1,223,914
Award Phase
2
Solicitation Topic Code
-----

Principal Investigator
Steven Francis LeBoeuf

Company Information

Valencell Inc

4601 Six Forks Road Suite 103
Raleigh, NC 27609
   (919) 747-3668
   info@valencell.com
   www.valencell.com

Research Institution

----------

Phase I

Contract Number: ----------
Start Date: ----    Completed: ----
Phase I year
2007
Phase I Amount
$191,942
This Small Business Technology Transfer (STTR) Phase I project will demonstrate the feasibility of a novel multi-wavelength light-emitting diode (LED) for transdermal health monitoring of various blood metabolites simultaneously in real time. With independent control of up to 12 spectrally narrow wavelengths, ranging from deep-UV to mid-IR, from a single 1 mm2 LED die, the company's compact multi-wavelength LED will revolutionize traditional pulse oximetry with unprecedented functionality at a significantly lower cost. In contrast with traditional dual-wavelength pulse oximetry, which primarily measures the ratio of oxygenated to deoxygenated blood, the proposed multi-wavelength LED will enable the real-time analysis several additional metabolites critical to health monitoring via the same noninvasive paradigm. Furthermore, combining 12 LEDs into one self-aligned device precludes the need for expensive packaging and complex optical alignment. The medical impact of dual-wavelength pulse oximetry, in both saving lives and reducing healthcare costs, has encouraged the development of broader platforms using additional optical wavelengths. Incorporating 3 or more independently controlled wavelengths has been shown to enable the real-time monitoring of multiple health factors while further reducing readout errors - thus saving more lives. Beyond blood oxygen monitoring, a real-time noninvasive assessment of renal and hepatic health can be realized by integrating several wavelengths in the same clinically accepted pulse oximetry paradigm. The proposed multi-wavelength single-die approach surmounts these limitations by providing independent control of several wavelengths from a single, self-aligned, compact LED. Integrating these advanced, cost-effective optical sources into traditional pulse oximetry opens up new markets in noninvasive metabolic monitoring for paramedics, physical therapists, drug discovery, and home healthcare. As a spectroscopic source, other applications include air-quality/pollution monitoring and agricultural/industrial controls

Phase II

Contract Number: ----------
Start Date: ----    Completed: ----
Phase II year
2008
Phase II Amount
$1,031,972
This Small Business Technology Transfer (STTR) Phase II project, in collaboration with North Carolina State University, will develop and validate an innovative, mobile, multiwavelength pulse oximetry module for noninvasive health monitoring of various blood metabolites simultaneously in real time. At the heart of this pulse oximetry module will be a novel multiwavelength emitter having independent control of up to nine spectrally narrow wavelengths, ranging from blue to mid-IR, emitting from a single 1 mm2 LED die. In contrast with traditional dual-wavelength pulse oximetry, which measures oxygen saturation in the blood, the proposed multiwavelength LED will enable real-time analysis several additional metabolites critical to health monitoring via the same noninvasive paradigm. Furthermore, the individually controlled self-aligned wavelengths enable superior motion artifact cancellation, which is essential for eHealth and mobile fitness applications. The key objectives of this feasibility study are to: Demonstrate luminescent films with peak emissions from 400-1100 nm Integrate these films into a compact multiwavelength pulse oximetry module Optimize novel pulsing algorithms for multiwavelength pulse oximetry Validate the mobile multiwavelength pulse oximetry module in a lab setting The medical impact of dual-wavelength pulse oximetry, in both saving lives and reducing healthcare costs, has encouraged the development of broader platforms using additional optical wavelengths. Incorporating 3 or more independently controlled wavelengths has been shown to enable the real-time monitoring of multiple health factors while further reducing readout errors ? thus saving more lives. Beyond blood oxygen monitoring, a real-time noninvasive assessment of renal and hepatic health can be realized by integrating several wavelengths in the same clinically accepted pulse oximetry paradigm. Though multispectral pulse oximetry systems incorporating several optical sources have been successfully demonstrated by physicians and industry leaders, incorporating multiple LEDs (made from dissimilar semiconductors) has led to costly reliability errors and even product recalls. If successful the proposed mobile, multiwavelength single-die approach surmounts these limitations by providing independent control of several wavelengths from a single, self-aligned, compact LED. Integrating these advanced, cost-effective optical sources into traditional pulse oximetry opens up new markets in noninvasive metabolic monitoring for clinical research, paramedics, physical therapists, drug discovery, consumer eHealth markets, and home healthcare. As a spectroscopic source, other applications include air-quality/pollution monitoring and agricultural/industrial controls