SBIR-STTR Award

Portable Liquid Chromatograph for Point-Of-Care Monitoring of Illicit Substances
Award last edited on: 3/30/21

Sponsored Program
STTR
Awarding Agency
NIH : NIDA
Total Award Amount
$135,024
Award Phase
1
Solicitation Topic Code
-----

Principal Investigator
Luke Tolley

Company Information

Axcend Corporation (AKA: Axcend LLC)

5252 North Edgewood Drive Suite 185
Provo, UT 84604
   (801) 405-9545
   info@axcendcorp.com
   www.axcendcorp.com

Research Institution

Rowan University

Phase I

Contract Number: 1R41DA045382-01A1
Start Date: 9/15/18    Completed: 8/31/19
Phase I year
2018
Phase I Amount
$135,024
Point-of-care (POC) testing of clinical samples for the presence of illegal substances and their metabolites is important for monitoring substance use disorders, employment screening, and legal matters relating to drug abstinence. Typical immunoassay screening methods suffer from higher false testing rates and do not provide quantitative information. Confirmatory tests that are used for quantitative analysis rely on chromatographic separations coupled with mass spectrometric (MS) detection, which requires expensive instrumentation and technical expertise for operation. In this research project, a prototype liquid chromatography (LC) instrument with integrated LED-UV detection will be developed for the purpose of POC screening of illicit drugs in clinical samples. The system includes integrated separation column cartridges, which makes column installation much simpler than with traditional instrumentation that requires additional tubing and fittings. A control program that runs on a miniaturized computer with an integrated touch-screen user interface is then used for instrument control and data acquisition. A method library for the separation of different classes of illicit substances will be developed on standard LC instrumentation using a variety of columns packed with different particle types and stationary phase selectivities. These methods will then be translated to the prototype system where users will be able to select a method for a given drug test panel, which reduces the technical expertise required to obtain concentration data on the tested samples. With this instrument, the integrated column cartridge is designed for dual LED-UV detection so that a single analyte is measured at two different absorbance wavelengths to provide positive identification using a new data analysis tool referred to as the “detection capacity”. The absorbance ratio for a given peak provides qualitative identification, which will ensure that each analyte is accounted for individually during the separation. Potential customers for this new products currently involved in the analysis of illicit substances will collaborate on the project to ensure that the results correlate well with the current methods employed for this application. The results generated by this new system will be faster and provide more analyte information that the standard immunoassay screening tests currently used, providing an important new commercial tool for POC drug monitoring.

Public Health Relevance Statement:
Project Narrative Point-of-care monitoring of illegal substance abuse typically relies on immunoassay-based qualitative methods to analyze clinical samples. This project focuses on the development of a portable liquid chromatography system with integrated user-control software that can be used to perform point-of-care analyses of illicit drug concentrations in such samples with more information provided than these current screening methods.

Project Terms:
American; analytical method; base; Bedside Testings; Biological Assay; capillary liquid chromatography; Chromatography; Clinic; Clinical; Cocaine; Collaborations; Computer software; Computers; cost; cost effective; Coupled; Data; data acquisition; Data Analyses; design; Detection; Development; drug abstinence; Drug Monitoring; Drug Prescriptions; Drug Targeting; drug testing; Drug usage; Electronics; Employment; Ensure; Enzyme-Linked Immunosorbent Assay; Evaluation; Forensic Medicine; Goals; Heroin; Human Resources; illicit drug use; Illicit Drugs; Immunoassay; improved; Individual; Industry Standard; instrument; instrumentation; Laboratories; Legal; Libraries; Liquid Chromatography; Liquid substance; Marijuana; Mass Chromatography; Mass Fragmentography; Measures; Methamphetamine; Methods; miniaturize; Molecular Weight; Monitor; novel; operation; particle; Performance; Phase; point of care; portability; Power Sources; Prevalence; programs; prototype; Qualitative Methods; Research; Research Project Grants; Running; Sampling; screening; Sorbus; Substance abuse problem; Substance Use Disorder; System; Systems Analysis; Technical Expertise; Techniques; Testing; Time; tool; touchscreen; Translating; United States Substance Abuse and Mental Health Services Administration; Universities; Vi

Phase II

Contract Number: ----------
Start Date: 00/00/00    Completed: 00/00/00
Phase II year
----
Phase II Amount
----