SBIR-STTR Award

User-Centered Control of Hearing Aid Signal Processing
Award last edited on: 8/12/15

Sponsored Program
SBIR
Awarding Agency
NIH : NIDCD
Total Award Amount
$1,023,884
Award Phase
2
Solicitation Topic Code
-----

Principal Investigator
Andrew T Sabin

Company Information

Ear Machine LLC

4332 Terri Lyn Lane
Northbrook, IL 60062
   (773) 800-9058
   contact@ear-machine.com
   www.ear-machine.com
Location: Single
Congr. District: 10
County: Cook

Phase I

Contract Number: 1R44DC013093-01
Start Date: 4/12/13    Completed: 9/30/13
Phase I year
2013
Phase I Amount
$155,846
Finding the signal processing parameter values that are most appropriate for an individual patient is one of the essential components of hearing aid fitting. In common practice, the hearing aid user only plays a small role in selecting these values. This proposal describes a data-driven method for empowering users to select their desired parameter values by adjusting two intuitive controllers (loudness and tone) that are displayed on consumer-level mobile devices that communicate wirelessly with the hearing aids. The primary innovation of this approach centers on large-scale analyses recognizing that systematic patterns in hearing loss configuration and in sound quality preference can be leveraged to reduce the dimensionality of an otherwise enormous space of potential combinations of parameter values. The resulting Dimension-Reduced Controllers (DRCs) make the most common combinations of signal processing parameter values easily accessible to the user, each controller manipulating numerous signal processing parameter values. In Phase I we will use DRCs with simulated hearing aids to explore the reliability, sound quality, and overall gain of the resulting hearing aid fits. In Phase II we will conduct a series of field trials where e examine users' abilities to adjust real hearing aids in real-world settings via mobile devices. In this Phase we will also develop market-ready mobile applications as well as communication protocols that use the wireless radios that are built into common mobile devices. We will evaluate these DRCs both as a tool to "fine- tune" the hearing aid parameter values after the prescription is applied and as stand-alone fitting method.

Public Health Relevance Statement:


Public Health Relevance:
In the United States, where more than 36 million people require treatment for their hearing loss, fewer than 20% actually seek help, leading to large segments of the population that have decreased quality of life. Some of the most significant barriers to hearing aid adoption are the high cost to the patient, and the low perceived benefit of the device. The mobile applications described in this proposal will both decrease cost to the patient by reducing the number of necessary clinical visits, and increase the perceived benefit to the patient by letting them rapidly address any complaints in the problematic environment. !

Project Terms:
Address; Adoption; base; Clinical; commercialization; Communication; Computer software; computerized data processing; cost; Data; design; Development; Devices; Dimensions; empowered; Environment; Hearing; Hearing Aids; hearing impairment; help-seeking behavior; Individual; innovation; Licensing; Loudness; Marketing; Methods; Patients; Pattern; Phase; Play; Population; preference; Protocols documentation; public health relevance; Quality of life; Radio; rapid technique; response; Role; Series; Simulate; simulation; sound; Speech Intelligibility; Speech Perception; Tablets; Technology; Testing; Time; tool; United States; Visit; Wireless Technology; Work

Phase II

Contract Number: 4R44DC013093-02
Start Date: 00/00/00    Completed: 00/00/00
Phase II year
2014
(last award dollars: 2015)
Phase II Amount
$868,038

Finding the signal processing parameter values that are most appropriate for an individual patient is one of the essential components of hearing aid fitting. In common practice, the hearing aid user only plays a small role in selecting these values. This proposal describes a data-driven method for empowering users to select their desired parameter values by adjusting two intuitive controllers (loudness and tone) that are displayed on consumer-level mobile devices that communicate wirelessly with the hearing aids. The primary innovation of this approach centers on large-scale analyses recognizing that systematic patterns in hearing loss configuration and in sound quality preference can be leveraged to reduce the dimensionality of an otherwise enormous space of potential combinations of parameter values. The resulting Dimension-Reduced Controllers (DRCs) make the most common combinations of signal processing parameter values easily accessible to the user, each controller manipulating numerous signal processing parameter values. In Phase I we will use DRCs with simulated hearing aids to explore the reliability, sound quality, and overall gain of the resulting hearing aid fits. In Phase II we will conduct a series of field trials where e examine users' abilities to adjust real hearing aids in real-world settings via mobile devices. In this Phase we will also develop market-ready mobile applications as well as communication protocols that use the wireless radios that are built into common mobile devices. We will evaluate these DRCs both as a tool to 'fine- tune' the hearing aid parameter values after the prescription is applied and as stand-alone fitting method.

Thesaurus Terms:
Address;Adoption;Base;Clinical;Commercialization;Communication;Computer Software;Cost;Data;Design;Development;Devices;Dimensions;Empowered;Environment;Handheld Mobile Device;Health;Hearing;Hearing Aids;Hearing Impairment;Help-Seeking Behavior;Individual;Innovation;Licensing;Loudness;Marketing;Methods;Mobile Application;Patients;Pattern;Phase;Play;Population;Preference;Protocols Documentation;Quality Of Life;Radio;Rapid Technique;Response;Role;Series;Signal Processing;Simulate;Simulation;Sound;Speech Intelligibility;Speech Perception;Tablets;Technology;Testing;Time;Tool;United States;Visit;Wireless Technology;Work;