SBIR-STTR Award

Novel RF Coils for Imaging Neonates
Award last edited on: 8/30/04

Sponsored Program
SBIR
Awarding Agency
NIH : NCI
Total Award Amount
$1,586,072
Award Phase
2
Solicitation Topic Code
-----

Principal Investigator
Ravi Srinivasan

Company Information

Advanced Imaging Research Inc (AKA: Sree Medical Systems)

4700 Lakeside Avenue Suite 400
Cleveland, OH 44114
   (216) 426-1461
   info@sreemedical.com
   sales@sreemedical.com
Location: Single
Congr. District: 11
County: Cuyahoga

Phase I

Contract Number: 1R43CA096029-01
Start Date: 00/00/00    Completed: 00/00/00
Phase I year
2002
Phase I Amount
$257,110
This application is submitted in response to NCUBIP PAR-01-102, "Development of Novel Imaging Technologies for In-Vivo Imaging". A overall goal of this project is to facilitate routine head/neck imaging at 3T, which at present is limited to head MRI. In Phase I, novel RF coil prototypes capable of high-resolution head/neck imaging in a clinical 3T setting will be developed. These prototypes will then be tested with phantoms and volunteers prior to clinical use. Phase II will involve extending the proven Phase I prototypes to include phased array designs and developing new RF coil arrays for high-resolution imaging of the head/neck tumors at 3T. This research is intended to facilitate detection of early changes preceeding the development of a disease, large cancer screening applications, for diagnosis, staging and monitoring the effects of therapy and for the use of image guided interventional procedures in patients with head/neck cancers. This we believe will be a substantial benefit to mankind.

Thesaurus Terms:
biomedical equipment development, electric field, head /neck neoplasm, magnetic resonance imaging, radiowave radiation electrical conductance bioimaging /biomedical imaging, clinical research, human subject, phantom model

Phase II

Contract Number: 9R44MH070709-02A1
Start Date: 00/00/00    Completed: 00/00/00
Phase II year
2003
(last award dollars: 2004)
Phase II Amount
$1,328,962

A long-term goal is to permit routine magnetic resonance examinations of critically ill pre and term neonates. We intend to accomplish this by adapting the radio-frequency (RF) coils developed in this project to the stand-alone incubator system developed elsewhere. More specifically, this proposal will develop high performance RF coils to enable high resolution imaging of the brain, spine and heart of sick pre and term neonates. Our coils will be interfaced to General Electric (Signa), Siemens (Symphony, Sonata) and Philips (Eclipse) 1.5T and GE 3T Magnetic Resonance systems. All of the RF coils developed will be systematically evaluated with phantoms and compared to existing devices. This will be followed by clinical verifications on a small number of ill patients with the assistance of our collaborators from the neonatology and radiology departments, on the 1.5 and 3T GE Signa at the Children's Hospital of Los Angeles and 1.5T Philips Eclipse MRI at the MetroHealth Medical Center. In addition, specific absorption rate (SAR) measurements will be made for our transmit/receive coils using the energy per pulse method at 1.5T and 3T. With the incubator system, sick neonates can be safely transported and scanned using MR. High quality data obtained with high signal-to-noise (S/N) custom coils may assist in the prognosis/diagnosis of illnesses which in turn may lead to prompt clinical (surgical, pharmaceutical) interventions which in turn may save many precious lives. This we believe will be a significant benefit to mankind. The significance of the work proposed is paramount