SBIR-STTR Award

Rapid Concentration of Viruses from Water
Award last edited on: 7/7/2010

Sponsored Program
SBIR
Awarding Agency
EPA
Total Award Amount
$294,987
Award Phase
2
Solicitation Topic Code
-----

Principal Investigator
Fu-Chih Hsu

Company Information

Scientific Methods Inc (AKA: SMI)

12441 Beckley Street
Granger, IN 46530
   (574) 277-4078
   info@scientificmethods.com
   www.scientificmethods.com
Location: Single
Congr. District: 02
County: St. Joseph

Phase I

Contract Number: ----------
Start Date: ----    Completed: ----
Phase I year
2009
Phase I Amount
$70,000
In the United States, several high profile outbreaks of waterborne illness during the past 15 years have highlighted the need for solutions to drinking water contamination. Several recent studies suggest that approximately 20 percent of the surface and ground source waters in the U.S. are contaminated with viruses. There is very little data, however, on virus occurrence in drinking water, which is mostly due to the absence of efficient methodologies that enable concentration and detection of viruses from water samples. Most current methods are labor or time intensive, expensive, or impractical. Therefore, there is an acute need for the development of concentration and detection technologies that enable efficient assay of viruses in water samples; these methods should be designed to be conducted directly in the field. Scientific Methods, Inc., has designed a concentration device that can capture viruses from large amounts of water. This device completely eliminates the need for a secondary concentration step and also increases the speed of concentration. The objective of this project is the development of an integrated detection method that includes capture of viruses from large volumes of water followed by detection of viruses by multiplex real-time, reverse-transcriptase polymerase chain reaction (RT-PCR). This project directly targets the following 2008 SBIR Phase I Research Topic: D. Drinking Water and Water Monitoring; Improved detection and measurement techniques for microbial pathogens. During Phase 1, two Specific Aims will be completed including: (1) optimization of the sampling and concentration device, and demonstration of the ability to simultaneously capture two viruses from moderate (40-60 liters) volumes of tap water, river water, and irrigation water within 1-3 hours; and (2) demonstration that both viral RNA and DNA can be simultaneously extracted directly without elution, and detected and quantified by a multiplex real-time RT-PCR assay. During the Phase II period, Scientific Methods will develop a multiplex isothermal RT-PCR assay, so that both the viral capture and detection steps can be completed directly in the field. Also, we will conduct in-field sampling of ground and surface water sources, and demonstrate the ability of the integrated capture and detection method to assay for the presence of viruses in these waters. It is expected that water testing companies, research laboratories, municipalities, and government agencies will make use of the capture and concentration device, either in combination with their own downstream detection assays, or with the isothermal-based RT-PCR assay that will be created during Phase II. Supplemental

Keywords:
small business, SBIR, EPA, virus, waterborne illness, drinking water, drinking water contamination, drinking water monitoring, surface water, ground water, virus detection, virus concentration, water sample, assay, concentration device, multiplex real-time, reverse-transcriptase polymerase chain reaction, tap water, irrigation water, river water, RNA, DNA, elution, measurement and monitoring

Phase II

Contract Number: ----------
Start Date: ----    Completed: ----
Phase II year
2010
Phase II Amount
$224,987
In the United States, several high profile outbreaks of waterborne illness during the past 15 years have highlighted the need for a solution to drinking water contamination. Several recent studies suggest that approximately 20 percent of surface and ground source waters in the United States are contaminated with viruses. There are very few data on virus occurrence in drinking water, however, which is mainly attributed to the absence of efficient methodologies that enable concentration and detection of viruses from water samples. Most current methods are labor or time intensive, expensive, or impractical. Therefore, there is an acute need for the development of concentration and detection technologies that enable efficient assay of viruses in water samples, and these methods should be designed to be conducted directly in the field. Scientific Methods, Inc. (SMI) has designed a concentration device that can capture viruses from large amounts of water. The device completely eliminates the need for a secondary concentration step and also increases the speed of concentration. The objective of this Phase II SBIR project is the development of an integrated detection method that includes capture of human enteric viruses as well as coliphages from large volumes of water followed by detection of the viruses by multiple real-time, reverse-transcriptase polymerase chain reaction (RT-PCR). During the Phase II period SMI plans to develop a multiple isothermal RT-PCR assay so that both the viral capture and detection steps can be completed directly in the field. Also, in-field sampling of ground and surface water sources will be conducted, and the ability of the integrated capture and detection method to assay for the presence of viruses in these waters will be demonstrated. It is expected that water testing companies, research laboratories, municipalities, and government agencies will make use of the capture and concentration device, either in combination with their own downstream detection assays or with the isothermal-based RT-PCR assay that will be created during Phase II. Supplemental

Keywords:
small business, SBIR, EPA, drinking water, water monitoring, drinking water contamination, viruses, virus concentration, virus detection, water pollution, virus assays, human enteric viruses, coliphages, groundwater, surface water, RT-PCR, reverse-transcriptase polymerase chain reaction, virus concentration, in-field sampling, detection assays,