SBIR-STTR Award

Field Analytical Method for Perchlorate
Award last edited on: 4/25/2006

Sponsored Program
SBIR
Awarding Agency
EPA
Total Award Amount
$70,000
Award Phase
1
Solicitation Topic Code
-----

Principal Investigator
Richard H Smith

Company Information

ThreeFold Sensors (AKA: IA Inc)

PO Box 1306
Ann Arbor, MI 48106
   (734) 995-9338
   jerb@threefoldsensors.com
   www.threefoldsensors.com
Location: Single
Congr. District: 06
County: Washtenaw

Phase I

Contract Number: ----------
Start Date: ----    Completed: ----
Phase I year
2006
Phase I Amount
$70,000
Perchlorate is a widely used component of solid fuel, missile and rocket propellants, explosives, and pyrotechnics. It has been shown to reduce iodide uptake into the thyroid gland. The U.S. Environmental Protection Agency (EPA) has found perchlorate contamination in 18 states and believes contamination may exist in as many as 39 states. In early January 2005, the National Academy of Sciences, in an EPA-sponsored study, recommended a reference dose (RfD) for human ingestion of 0.7 µg/kg/day, which suggests a maximum contaminant level (MCL) of 24.5 µg/L (ppb) or lower; several states allow between 1 and 6 µg/L. Based upon this recommendation, there is a need for field monitoring of perchlorate in ground and surface waters to test the effluent of remediation facilities and to determine soil cleanup levels. To provide a field analytical method, IA, Inc., has devised a technology that combines ion chromatography (IC), similar to that used in EPA Method 314, with specific perchlorate detection using a low detection limit ion selective electrode (ISE). Use of the perchlorate ISE as the detector results in lower interference from common anions than is found using Method 314. For this method, IA received a patent in 2004 (U.S. Patent No. 6,736,958). This method simplified and improved Method 314, as the ISE replaced both the conductivity detector and the suppression unit. It also improved the approach of measuring perchlorate by ISE, because the presence of sufficiently high levels of competing ions, measured without separation, can yield false positive results. The innovation of this Phase I research is to simplify and standardize electrode construction by casting the electrode on thin-walled, porous tubing after having defined free space. The objectives are to: (1) cast electrodes on a selection of porous tubing, selecting one that provides optimum robustness and reproducibility; (2) optimize electrode response by selecting the ionophore, plasticizer, and other ISE components; and (3) determine the selectivity obtained when using the perchlorate ISE as the detector for IC. Phase II will focus on optimizing calibration, developing analytical software, and field testing a prototype instrument. The resulting instrument will be suitable for field use, adaptable to batch analysis in the laboratory, and capable of remote sensing. Potential markets include U.S. Department of Defense contractors, environmental engineers and testing laboratories, state and municipal water authorities, and remediation firms. Supplemental

Keywords:
small business, SBIR, perchlorate, field analytical method, contaminant level, soil cleanup levels, missile propellants, rocket fuel, iodide uptake, thyroid gland, ion chromatography, ground water, surface water, water pollution, monitoring, analytical, maximum contaminant level, MCL, EPA

Phase II

Contract Number: ----------
Start Date: ----    Completed: ----
Phase II year
----
Phase II Amount
----