SBIR-STTR Award

New Technology to Improve Chemotherapy Safety for Cancer Patients and Health Workers
Award last edited on: 4/29/2026

Sponsored Program
SBIR
Awarding Agency
NIH : NCI
Total Award Amount
$548,377
Award Phase
1
Solicitation Topic Code
93.393
Principal Investigator
Prasad Sunkara

Company Information

Corvida Medical (AKA: J&J Solutions Inc~J & J Solutions Inc)

2261 Crosspark Road Suite 127
Coralville, IA 52241
   (800) 604-2235
   info@corvidamedical.com
   www.corvidamedical.com
Location: Single
Congr. District: 01
County: Johnson

Phase I

Contract Number: 1R43CA224598-01
Start Date: 5/4/2018    Completed: 4/30/2020
Phase I year
2018
Phase I Amount
$548,377
Manual drug compounding of chemotherapy medications permits deadly dosing errors and toxic drug exposure, posing unnecessary risks to patients and healthcare workers. Some automated drug compounding devices have been developed in response; however, poor drug containment/safety capabilities and prohibitive cost and size have limited widespread adoption of existing compounding devices. Corvida Medical has developed a working prototype for a patented, automated compounding device that will overcome the safety, cost, and size limitations of existing compounding equipment. As part of a previously funded SBIR Phase I/Phase II project, Corvida developed a disposable closed system drug transfer device (CSTD) to protect health care workers from toxic exposure to hazardous drugs used in cancer treatments. The Corvida R&D team has successfully validated and commercialized the Corvida CSTD, demonstrating its utility in the market. Preliminary data accumulated with our new automated compounding device prototype demonstrates feasibility of manipulation of components (vials, syringes and CSTD disposables), and shows accuracy and repeatability to be in the 90-95% range. Corvida now aims to further develop and validate a novel compounding device that integrates the advantages of automation technology, to enhance patient care, with the added containment/safety capabilities of a disposable CSTD, to optimize worker safety. This innovative, automated compounding-CSTD system will ensure reliable and accurate drug compounding to prevent patient medication errors and will interface with the disposable Corvida CSTD to reduce worker exposure to hazardous drugs. Further, our novel compounding device is small enough to operate within a Class II Biological safety Cabinet, so it will be available at a fraction of the cost and size of existing devices. In this Phase I project, we will demonstrate feasibility of our novel compounding equipment and validate the performance and usability of the device when integrated with the disposable Corvida CSTD. To achieve these goals, we will develop and engineer a beta prototype of the compounding device that meets preliminary specifications, functions with the Corvida CSTD, and is capable of undergoing further validation testing. We will then substantiate feasibility of the automated compounding-CSTD system through analytic validation testing for process reliability, accuracy, containment, sterility, and system throughput. We aim to show a minimum 95% reliability, 95% accuracy, containment and sterility that meet USP standards, and system throughput of at least 12 doses/hour. Successful completion of these studies will result in quantitative performance validation of an innovative, automated compounding device that works with the Corvida CSTD, providing compelling proof-of-concept to support continued development in Phase II. The resulting commercialized technology will advance current clinical practice by providing accurate and reliable compounding to ensure patients are not victims of deadly errors and will also advance occupational safety by assuring health workers are not exposed to toxic drugs.

Public Health Relevance Statement:
NARRATIVE Every year, errors in chemotherapy preparation and delivery cause significant patient harm, including death. Manual drug preparation permits such dangerous errors, and further places health workers who care for cancer patients at risk of toxic exposure to hazardous drugs. We have developed an innovative, automated drug compounding device that provides reliable and accurate dose preparation to improve patient safety-and also interfaces with disposable closed system drug transfer device to protect health workers from harmful exposure. Terms: <5-FU; 5-Fluracil; 5FU; Actinic Rays; Adoption; Algorithms; Automation; Biological; Cancer Patient; Cancer Treatment; Cancers; Cessation of life; Clinic; Code; Coding System; Computer Models; Computer Simulation; Computer based Simulation; Computer software; Computerized Models; Containment; Dangerousness; Data; Death; Detection; Development; Development and Research; Devices; Diagnosis; Dose; Drug Compounding; Drug Exposure; Drug Preparation; Drug Therapy; Drug usage; Drugs; Engineering; Ensure; Equilibrium; Equipment; Exposure to; Failure; Finite Element Analyses; Finite Element Analysis; Fluoro Uracil; Fluorouracil; Fluoruracil; Fluouracil; Foundations; Funding; Goals; Grant; HPLC; Health; Health Care Providers; Health Personnel; Healthcare Providers; Healthcare worker; High Performance Liquid Chromatography; High Pressure Liquid Chromatography; High Speed Liquid Chromatography; Hospitals; Hour; Hydrogen Oxide; Imagery; Injections; Investments; Legal patent; Malignant Neoplasm Therapy; Malignant Neoplasm Treatment; Malignant Neoplasms; Malignant Tumor; Manuals; Mathematical Model Simulation; Mathematical Models and Simulations; Measures; Medical; Medication; Medication Errors; Motion; Occupational Safety; Outcome; Particulate; Patents; Patient Care; Patient Care Delivery; Patients; Pattern; Performance; Pharmaceutic Preparations; Pharmaceutical Preparations; Pharmacotherapy; Phase; Poisons; Preparation; Privatization; Process; R & D; R&D; Risk; SBIR; Safety; Sampling; Series; Services; Site; Small Business Innovation Research; Small Business Innovation Research Grant; Smoke; Software; Stainless Steel; Sterility; Stress; Surface; Syringes; System; Technology; Testing; Time; Toxic Chemical; Toxic Substance; Toxicant exposure; Training; UV light; UV radiation; Ultraviolet Rays; Validation; Variant; Variation; Vial; Vial device; Visualization; Water; Weight; Work; anti-cancer therapy; anticancer therapy; balance; balance function; base; cancer care; cancer therapy; chemotherapy; clinical practice; commercial application; computational modeling; computational models; computational simulation; computer based models; computerized modeling; computerized simulation; cost; design; designing; developmental; drug treatment; drug use; drug/agent; health care personnel; health care worker; health provider; health workforce; healthcare personnel; improved; in silico; innovate; innovation; innovative; malignancy; medical personnel; medication administration errors; meter; multidisciplinary; neoplasm/cancer; new technology; novel; novel technologies; operation; particle; patient safety; performance tests; poison; prevent; preventing; prototype; research and development; response; sterile; toxic compound; toxic exposure; treatment provider; trypticase soy; trypticase-soy broth; ultraviolet light; ultraviolet radiation; usability; virtual simulation