SBIR-STTR Award

Innovative Device to Improve Safety of Preparing and Administering Chemotherapy
Award last edited on: 9/3/19

Sponsored Program
SBIR
Awarding Agency
NIH : NCI
Total Award Amount
$4,805,396
Award Phase
2
Solicitation Topic Code
-----

Principal Investigator
Stephen Mitchell

Company Information

Corvida Medical (AKA: J&J Solutions Inc~J & J Solutions Inc)

2261 Crosspark Road Suite 127
Coralville, IA 52241
   (800) 604-2235
   info@corvidamedical.com
   www.corvidamedical.com
Location: Single
Congr. District: 01
County: Johnson

Phase I

Contract Number: 1R43CA153636-01
Start Date: 9/17/10    Completed: 6/30/11
Phase I year
2010
Phase I Amount
$249,799
Drugs used for cancer chemotherapy tend to be highly cytotoxic and genotoxic, with well-documented carcinogenic, mutagenic, and teratogenic effects. Long-term, occupational exposure to these highly toxic drugs presents serious health risks to the healthcare personnel who routinely prepare and administer chemotherapy, such as cancers, infertility, miscarriages, birth defects, spontaneous abortions, and congenital malformations. Leakage in the form of liquid, particulate, or vapor can occur during any of several steps in the process of compounding the drug and administering it to the patient, and several studies suggest the potential for workplace contamination is widespread. Closed system transfer devices (CSTDs) were originally developed to mitigate these risks, but the devices that are currently available in the marketplace suffer from a number of shortcomings, including leakage, needle sticks, inefficiencies, difficulty of use, and repetitive stress injuries. The objective of this Phase I SBIR proposal is to test the feasibility of a new, innovative disposable CSTD design that has the potential to provide superior drug containment capabilities. Feasibility will be determined by pursuing two specific aims. In Aim 1, this unique concept will be refined through a series of design iterations linked to fabrication and testing of rapid prototypes, culminating in production of a proof-of concept, working prototype that can be rigorously tested to establish its performance characteristics in Aim 2. Performance of the working prototype will be validated under real-life, process simulation conditions to determine whether it can contain leakage and maintain sterility during operation under the most challenging and stressful conditions encountered during drug compounding. Containment will be measured by sensitive visual and analytical methods, and sterility will be determined using United States Pharmacopeia standards for media fill. Successful completion of the phase I design and development studies will establish the groundwork for this novel, disposable CSTD as the cornerstone of a disruptive technology that will undergo further development in Phase II. As the population ages and the number of cancer patients grows, the demand for chemotherapy drug compounding is expected to increase, especially the preparation of tailored therapies for point-of-care use. The unique approach described in this proposal will benefit healthcare staff and patients alike by reducing the risks of occupational exposure and improving the accuracy of patient medications, while simultaneously increasing efficiencies and reducing costs. We anticipate our innovative CSTD will introduce unprecedented safety and efficiency improvements, strategically positioning J&J to capitalize on a rapidly growing $500 million market while reducing the risks associated with compounding and administering hazardous chemotherapy drugs. , ,

Public Health Relevance:
Millions of healthcare workers are at risk of exposure to hazardous drugs, such as chemotherapeutics used to treat cancer patients, during drug preparation and administration. Closed system transfer devices (CSTDs) were originally developed with the goal of protecting workers from the hazards of exposure to highly toxic drugs, but current devices have several shortcomings. This proposal describes an innovative design and approach for a new type of disposable CSTD that will provide better protection for healthcare workers and cancer patients alike, achieved by limiting the release of these hazardous drugs into the work environment.

Thesaurus Terms:
Address;Adoption;Adverse Experience;Adverse Effects;Adverse Event;Age;Ambulatory Care Facilities;Area;Birth Defects;Bypass;Ccop;Cancer Patient;Cancer, Oncology;Cancers;Cannot Achieve A Pregnancy;Care, Health;Cessation Of Life;Characteristics;Chemotherapy Protocol;Chemotherapy Regimen;Chemotherapy, Cancer, General;Chemotherapy-Oncologic Procedure;Clinic;Clinical;Clinics And Hospitals;Clinics Or Hospitals;Combination Chemotherapy Regimen;Community Clinical Oncology Program;Community Oncology;Computer-Aided Design;Computer-Assisted Design;Congenital Abnormality;Congenital Anatomic Abnormality;Congenital Anatomical Abnormality;Congenital Defects;Congenital Deformity;Congenital Malformation;Containment;Culture Media;Cumulative Trauma Disorders;Death;Detection;Development;Device Designs;Device Or Instrument Development;Devices;Difficulty Conceiving;Drug Compounding;Drug Preparation;Drug Residues;Drug Usage;Drugs;Engineering;Engineerings;Ensure;Environment;Environmental Pollution;Equipment;Exposure To;Extravasation;Flr;Failure (Biologic Function);Feedback;Fluorescein;Fluoresceins;Fungi, Filamentous;Generalized Growth;Goals;Growth;Hosp;Health;Health Care Providers;Health Personnel;Healthcare;Healthcare Providers;Healthcare Worker;Hospitals;Human;Human Resources;Human, General;Infertility;Injection Of Therapeutic Agent;Injections;Investigators;Job Environment;Job Location;Job Place;Job Setting;Job Site;Killings;Knowledge;Leakage;Legal Patent;Life;Link;Liquid Substance;Maintenance;Maintenances;Malignant Cell;Malignant Neoplasms;Malignant Tumor;Man (Taxonomy);Man, Modern;Manpower;Manuals;Manufactured Materials;Marketing;Measures;Medication;Medication Errors;Miscarriage;Modeling;Molds;Molecular Genetic Abnormality;Needle-Stick Injuries;Needle-Sticks;Needlestick Injuries;Needlesticks;Nursing Staff;Occupational Exposure;Oncology Programs;Outpatient Clinics;Overuse Injury;Overuse Syndrome;Particulate;Patents;Patients;Performance;Performance At Work;Pharmaceutic Preparations;Pharmaceutical Agent;Pharmaceutical Preparations;Pharmaceuticals;Pharmacies;Pharmacologic Substance;Pharmacological Substance;Pharmacopoeias;Pharmacy Facility;Phase;Population;Position;Positioning Attribute;Preparation;Pressure;Pressure- Physical Agent;Procedures;Process;Production;Protocol;Protocols Documentation;Puncture Procedure;Punctures;Quimioterapia;Repetition Strain Injury;Repetitive Motion Disorders;Repetitive Strain Injury;Repetitive Stress Injury;Reproducibility;Research Personnel;Researchers;Risk;Robot;Robotics;Running;Sbir;Sbirs (R43/44);Safety;Series;Sight;Simulate;Small Business Innovation Research;Small Business Innovation Research Grant;Solutions;Spillage;Spontaneous Abortion;Sterility;Surface;Syringes;System;System, Loinc Axis 4;Technology;Testing;Tissue Growth;Treatment Side Effects;United States;Urinary System, Urine;Urine;Validation;Vial;Vial Device;Vision;Visual;Work;Work Location;Work Place;Work-Site;Workplace;Worksite;Analytical Method;Base;Cancer Cell;Cancer Chemotherapy;Chemotherapy;Cost;Cytotoxic;Design;Designing;Device Development;Drug Use;Drug/Agent;Environmental Contaminant;Environmental Contamination;Experience;Failure;Fluid;Growth Media;Hazard;Health Care Personnel;Health Care Worker;Health Provider;Healthcare Personnel;Improved;Infertile;Innovate;Innovation;Innovative;Instrument Development;Job Performance;Liquid;Malignancy;Medical Personnel;Meetings;Microbial;Neoplasm/Cancer;Novel;Nursing Personnel;Oncology;Ontogeny;Operation;Personnel;Point Of Care;Pressure;Prevent;Preventing;Prototype;Public Health Relevance;Reconstitute;Reconstitution;Repetitive Motion Injury;Response;Robotic Device;Side Effect;Simulation;Sterile;Success;Therapy Adverse Effect;Treatment Adverse Effect;Treatment Provider;Unable To Bear Children;Vapor;Work Environment;Work Performance;Work Setting

Phase II

Contract Number: 2R44CA153636-02
Start Date: 9/17/10    Completed: 8/31/14
Phase II year
2012
(last award dollars: 2016)
Phase II Amount
$4,555,597

Chemotherapy drugs tend to be highly cytotoxic and genotoxic, with well-documented carcinogenic, mutagenic, and teratogenic effects. Long-term occupational exposure to these highly toxic drugs presents serious health risks (e.g., cancers, infertility, miscarriages, birth defects, spontaneous abortions, and congenital malformations) to over 5.5 million healthcare workers who are exposed to chemotherapy drugs each year. Liquid, particulate, or vapor leakage can occur during any of several steps in the process of compounding the drug and administering it to the patient, and several studies suggest the potential for workplace contamination is widespread. Closed system drug-transfer devices (CSTDs) were originally developed to mitigate these risks, but the devices now on the market suffer from key shortcomings, including leakage, needle sticks, inefficiencies, difficulty of use, and increased risk of repetitive stress injuries and compounding/delivery errors. Corvida's technology objective is to develop and commercialize a proprietary suite of medical devices that improve the safety of working environments for healthcare professionals and enhance the efficacy of patient treatments. Phase I successfully proved feasibility of the Corvida approach and the potential to overcome the limitations of current devices that leave healthcare workers unprotected. The Phase II goal is to fully validate this new CSTD with extensive testing and optimization. Phase II includes three aims to drive development of the Corvida CSTD and provide superior protection to healthcare workers. In Aim 1, the CSTD will be validated for design and production quality via published bench-top testing standards, including fluorescein sodium (UV solution) and titanium tetrachloride (visible vapor) tests. These tests will ensure that the CSTD meets or exceeds all relevant USP and ISO standards to validate that it achieves the intended design and production quality for performance and functionality as well as packaging and sterilization. In Aim 2, the CSTD will be tested to demonstrate that it achieves containment and maintains sterility under end-user process simulation conditions using naproxen sodium and trypticase soy broth. In Aim 3, end-users will use the Corvida CSTD to conduct compounding and simulated administration tasks (no drugs will be delivered to patients) in multiple pharmacy settings using two well established chemotherapy marker drugs: cyclophosphamide and fluorouracil. The Aim 3 study includes assessment of environmental surface contamination using analytic methods and will provide documentation of any device failures. An independent, certified industrial hygienist will collect and analyze wipe samples from designated surfaces to assess pre-and-post-CSTD contamination. Iterative design will be utilized as needed to refine the CSTD system to meet all success criteria. As envisioned-and based on the very promising Phase I results-upon completion of Phase II the Corvida CSTD will be the first to meet the NIOSH and USP CSTD definition, and the Corvida device will have been validated against all ISO standards and FDA requirements, culminating in 510(k) market clearance and enabling successful commercialization.

Public Health Relevance:
Millions of healthcare workers are at risk of exposure to hazardous drugs, such as chemotherapeutics used to treat cancer patients, during drug preparation and administration. Closed system transfer devices (CSTDs) were originally developed with the goal of protecting workers from the hazards of exposure to highly toxic drugs, but current devices have several shortcomings. This proposal describes an innovative design and approach for a new type of disposable CSTD that will provide better protection for healthcare workers and cancer patients alike, achieved by limiting the release of these hazardous drugs into the work environment.